• Air Jacket CO2 Incubator Water Jacket CO2 Incubator
  • Air Jacket CO2 Incubator Water Jacket CO2 Incubator
  • Air Jacket CO2 Incubator Water Jacket CO2 Incubator
  • Air Jacket CO2 Incubator Water Jacket CO2 Incubator

Air Jacket CO2 Incubator Water Jacket CO2 Incubator

After-sales Service: Instruction
Warranty: 1 Year
Application: Hospital, Lab
Customized: Non-Customized
Certification: CE, ISO
Structure: Portable
Samples:
US$ 3250/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
BIO-40RHP
Material
Steel
Type
Lab Thermostatic Oil Bath
Transport Package
Wooden Box
Trademark
BEING
Origin
Jiangsu
Production Capacity
500000

Product Description

Product Description

Air Jacket CO2 Incubator Water Jacket CO2 Incubator

Air Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 Incubator
BIO-RWP series water jacket CO2 incubator touch screen
Water jacket CO2 incubator is designed for long time stable culture. The control temp. is stable and accurate, suitable for the
microorganisms culture with long cycle and not need to open door often.
Intelligent touch screen controller
Replace traditional button operation to touch screen interface.
It can display on time performance curve. You can check the temp., humidity
(option) and CO2 concentration three group curves changes at the same time.
And abnormal alarm and door open or close message.
When parameters are set, the controller will lock the screen automatically, it
avoid unauthorized person wrong operation on the machine.
72 hours machine performance inquiry, it is convenient for user to check
abnormal situation and track historical running information.
RS-485 communication port as options can be remote control on computer
for monitoring the running and start or close the machine.
CO2 concentration sensor
You may need to open door frequently during experiment, infrared sensor
is the best choice under this circumstances. Our infrared sensor is very
sensitive to CO2 concentration varies and it will be not affected by inside of
incubator chamber conditions, measured accurately. It doesn't like traditional
thermal probe that will be sensitive to chamber temp., and humidity that lead
to incorrect CO2 concentration data.
If open the door for 30s and close the door, within 3 min the CO2 concentration
can resume to the set value 5%.Even if there are many people use the same
machine and frequently open and close door, the inside chamber can still
maintain CO2 concentration stable and uniform.
Temperature control and monitoring system
A.Incubator temperature control system
PT100 temp. sensor keeps inside chamber temperature accurate. It can
adjust the heating power according to the temp. differences between actual
temp. in the chamber and set temp. to make sure temp. in the chamber is
accurate. It can resume experiment temp. in 3 min after user open and close
door to take samples.
B.Water jacket heating system
Water jacket heating method to ensure working chamber temperature is uniform,
when it is power off, the chamber can maintain the temp. for a long time.
C.Door heating system
Outer door ring has heating function. The temperature of door ring will be a
little bit higher than temp. in the chamber to prevent condensed water coming
from the inner glass door. It facilitates observe the experiment process, also it
avoid the biological pollution possibility due to the condensed water from the
inner glass door.
D.Over temp. protection system
It is an independent backup temp. control system besides the CO2 incubator
temp. control system. When the incubator temp. control system failed and
caused temp. lose control, the chamber temp. reaches to the over temp.
limiter set value, over temp. protection system will cut down the heating and
alarm audible with light.
Documentation and failure diagnostic display (Option)
All data can be stored through RS485 port, if any failures, user can read the
diagnostic message and data from computer at any time.
Air Jacket CO2 Incubator Water Jacket CO2 Incubator
Pollution proof control
A.Ultraviolet sterilization
The ultraviolet lamp is placed at the back top of the chamber. It can sterilize the chamber regularly. It kills
chamber recycle air bacteria and float bacteria from water tray or slop water in the bottom, effectively
prevent pollution during cell culture period.
B.HEPA efficient filters
The CO2 gas quality is a important factor to judge cell culture in the CO2 incubator. HEPA high efficient
filters can filter bacteria and dust in the air. It eliminates cross contamination from outer air to incubator
chamber air and keep the chamber inside aseptic. Close the door for 5 min, inside air can fast resume to
hundred grade clean. HEPA air filter is easy to disassemble without any special instruments.
C.Micro biological HEPA filter
CO2 access port equips micro biological HEPA filter, it can filters diameter ≥0.3um Particles like CO2 gas
bacteria and dust, the efficient reaches to 99.99%.
Cycle fan speed adjustable automatically
Cycle fan speed can be adjusted automatically. When chamber temp. is stable, the fan speed will be lower down, the speed will
be adjusted to a suitable speed that the cell can growth. It avoids the fast fan speed that evaporating the samples.
CO2 inlet control system
We supply pressure release valve together with the equipment. It can control the pressure stable.
The system has pressure protection function, it prevents over pressure or low pressure to the pipes.
Safe Functions
High and low temp. and over temp. alarm Chamber sensor failure alarm
Door temp. sensor failure alarm Over temp sensor failure alarm
CO2 condensation too high or too low alarm Independent temp. limiter alarm
Door open too long alarm Disinfection and sterilization status reminder
Air Jacket CO2 Incubator Water Jacket CO2 Incubator
Product Parameters
Model BIO-170RWP BIO-240RWP
Electrical requirement AC220V/50Hz
Input power 700W 1000W
Heating power Water jacke
Temp. control range RT+5-50ºC
Work environment temp +5-30ºC
Temp. accuracy ±0.1ºC
CO2    control range 0-   20%
CO2 control  accuracy ±0.1%(IR sensor)
CO2   restore time Door open 30s,recovery to 5%)≤3min
Temp. restore time (Door open 30s,recovery to 37ºC)≤8min
Related humidity Nature vaporate > 95%(Can equip with related humidity digital display)
Volume 170L 240L
Chamber size W×D×H(mm) 530×460×720 600×520×780
Overall size W×D×H(mm) 684×700×960 754×760×1020
Standard shelves qty 3 pcs
Steriization UV sterilization+HEPA sterilization
Note: All parameters are measured at 25ºC

BPN-CRH series air jacket CO2 incubator LCD type
LCD screen controller
LCD screen, micro computer PID control that can display temp. CO2
concentration, related humidity, operation failure reminder and menue
operation are easily to observe and use.
CO2 concentration sensor
You may need to open door frequently during experiment, infrared sensor
is the best choice under this circumstances. Our infrared sensor is very
sensitive to CO2 concentration varies and it will be not affected by inside of
incubator chamber conditions, measured accurately. It doesn't like traditional
thermal probe that will be sensitive to chamber temp., and humidity that lead
to incorrect CO2 concentration data.
If open the door for 30s and close the door, within 3 min the CO2 concentration
can resume to the set value 5%.Even if there are many people use the same
machine and frequently open and close door, the inside chamber can still
maintain CO2 concentration stable and uniform.
Temperature control and monitoring system
A.Incubator temperature control system
PT100 temp. sensor keeps inside chamber temperature accurate. It can
adjust the heating power according to the temp. differences between actual
temp. in the chamber and set temp. to make sure temp. in the chamber is
accurate. It can resume experiment temp. in 3 min after user open and close
door to take samples.
B.Door heating system
Outer door ring has heating function. The temperature of door ring will be a
little bit higher than temp. in the chamber to prevent condensed water coming
from the inner glass door. It facilitates observe the experiment process, also it
avoid the biological pollution possibility due to the condensed water from the
inner glass door.
C.Over temp. protection system
It is an independent backup temp. control system besides the CO2 incubator
temp. control system. When the incubator temp. control system failed and
caused temp. lose control, the chamber temp. reaches to the over temp.
limiter set value, over temp. protection system will cut down the heating and
alarm audible with light.
Pollution proof control
A.90 degree high temp. high humidity sterilization system (RHP)
It can thoroughly sterilize the chamber (Including temp. sensor, CO2 concentration sensor, fan, shelves and brackets etc) with
high temp and high humidity. It eliminates bacteria, mold, mycoplasma etc microbiology those will pollute the microorganisms cell
culture and provides a safe experiment environment.
B.HEPA efficient filters
The CO2 gas quality is a important factor to judge cell culture in the CO2 incubator. HEPA high efficient filters can filter bacteria and
dust in the air. It eliminates cross contamination from outer air to incubator chamber air and keep the chamber inside aseptic.
Close the door for 5 min, inside air can fast resume to hundred grade clean. HEPA air filter is easy to disassemble without any
special instruments.C.Micro biological HEPA filter.
CO2 access port equips micro biological HEPA filter, it can filters diameter ≥0.3um Particles like CO2 gas bacteria and dust, the
efficient reaches to 99.99%.
Air Jacket CO2 Incubator Water Jacket CO2 Incubator
Model BPN-40CRH BPN-8OCRH BPN-150CRH BPN-190CRH BPN-240CRH
Electrical requirement AC220V/50Hz
Input power 350W 500W 750W 750W 950W
Heating power Air jacket micro computer PID contro
Temp. control range RT+5-55ºC
Work environment temp +5-30ºC
Temp.accuracy ±0.1ºC
CO2    control range 0-   20%
CO2    control accuracy ±0.1%(IR sensor)
CO2    restore time (Door open 30s, recovery to 5%)≤3min
Temp.restore time (Door open 30s, recovery to 37ºC)≤8min
Related humidity Nature vaporate > 95%(Can equip with related humidity digital display)
Volume 40L 80L 155L 190L 240L
Chamber size W×D×H(mm) 400×286×350 400×450×500 480×530×610 520×530×390 600×630×670
Overall size WxD×H(mm) 590×440×576 590×687×790 670×767×880 708×710×1030 790×837×940
Standard shelves qty 2pcs 3 pcs
Sterilization UV sterilization+HEPA filter
Company Profile

Air Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 IncubatorAir Jacket CO2 Incubator Water Jacket CO2 Incubator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now